2-40HP R404a Water Cooled Condensing Unit,Refrigeration Units Used For Cold Storage,Chiller And Freezer Room
Semi-hermetic water-cooled unit to or Copeland compressor as the main engine, power from 2HP-50HP, shell-and-tube water-cooled condenser using a famous domestic brand, pure copper pipe products, high heat transfer efficiency. Marine water-cooled condenser adopts anti-seawater design, tube plate, end cover and Shell after special anti-corrosion treatment, heat exchange tubes are made of B10, HA177-1 and other materials, and both ends of the water cover can be removed, easy to clean.
Features:
1.Special Valve design, high efficiency and stability, long service life.
2.Refrigeration capacity, energy efficiency ratio (COP) higher than other brands of compressors 20%.
3. Good low temperature performance, for R22 refrigerant, single-stage compressor evaporation temperature up to-40 °c
4.Used in a variety of refrigerants (R12, R22, R502, R134a, R404a, R507) . Compliance with environmental requirements.
5. Using split coil to start, reduce the starting current, reduce the impact on the power grid, the motor has special design technical parameters and newly developed stator and rotor components, increased efficiency and power factor.
6. A wide range of applications: Buzel compressor is divided into high-temperature type and low-temperature type, high-temperature type evaporation temperature up to 12.5 °C, low-temperature type single-stage compressor evaporation temperature up to (R22)-40 °C, double-stage compressor evaporation temperature up to (R22)-50 °C. If R404A or R507 is used, the evaporation temperature will be lower, reaching-70 °C.
7. Energy Regulation Wide: 4 cylinder compressor energy regulation range 50% , 100% , 6 cylinder compressor energy regulation range 33% , 66% , 100% . When the refrigeration system load changes when effective regulation to reduce operating costs.
8.Built-in motor overload protector (INT69VS) , effective protection of motor due to increased refrigeration system load or insufficient refrigerant return refrigeration system, resulting in motor overload, overheating.
9. In order to prevent the starting current is too large, you can also choose to uninstall the starting device.
Specifications:
Based on -15℃ evaporating temperature and 18℃ suction temperature and 0℃ K subcooling for the liquid refrigerant.
Temperature range | Model (R404) | Horse Power | Applicable coldroom |
High temp | 2HES-2Y | 2HP | Chiller room |
High temp | 2GES-2Y | 2HP | Chiller room |
High temp | 2FES-3Y | 3HP | Chiller room |
High temp | 2EES-3Y | 3HP | Chiller room |
High temp | 2DES-3Y | 3HP | Chiller room |
High temp | 2CES-4Y | 4HP | Chiller room |
High temp | 4FES-5Y | 5HP | Chiller room |
High temp | 4EES-6Y | 6HP | Chiller room |
High temp | 4DES-7Y | 7HP | Chiller room |
High temp | 4CES-9Y | 9HP | Chiller room |
High temp | 4VES-10Y | 10HP | Chiller room |
High temp | 4TES-12Y | 12HP | Chiller room |
High temp | 4PES-15Y | 15HP | Chiller room |
High temp | 4NES-20Y | 20HP | Chiller room |
High temp | 4HE-25Y | 25HP | Chiller room |
High temp | 4GE-30Y | 30HP | Chiller room |
High temp | 6HE-35Y | 35HP | Chiller room |
Low temp | 2FES-2Y | 2HP | Freezer room |
Low temp | 2EES-2Y | 2HP | Freezer room |
Low temp | 2DES-2Y | 2HP | Freezer room |
Low temp | 2CES-3Y | 3HP | Freezer room |
Low temp | 4FES-3Y | 3HP | Freezer room |
Low temp | 4EES-4Y | 4HP | Freezer room |
Low temp | 4DES-5Y | 5HP | Freezer room |
Low temp | 4CES-6Y | 6HP | Freezer room |
Low temp | 4TES-9Y | 9HP | Freezer room |
Low temp | 4PES-12Y | 12HP | Freezer room |
Low temp | 4NES-14Y | 14HP | Freezer room |
Low temp | 4HE-18Y | 18HP | Freezer room |
Low temp | 4GE-23Y | 23HP | Freezer room |
Low temp | 6HE-28Y | 28HP | Freezer room |
Low temp | 6GE-34Y | 34HP | Freezer room |
Low temp | 6FE-44Y | 44HP | Freezer room |